Contrast Delivery System

PRODUCT

제품소개

ACIST CVi™

Contrast Delivery System

KNOW and CONTROL

how much contrast is used.

CVi delivers the power to improve patient safety,
minimizing the risk of contrast induced acute kidney injury (CI-AKI) for coronary
catheterizations when compared to manual injection of contrast media.
ACIST CVi® is a sophisticated system providing precise control of
contrast injections for all your interventional and diagnostic angiographic procedures.
From small injections in the coronaries to large volumes in the ventricles and
peripheral vasculature. It’s the advanced technology
that physicians and staff can rely on for controlled delivery of contrast.
As interventional procedures become more complex,
it’s important to take steps to reduce the incidence of CI-AKI2
and also reduce the radiation exposure in clinicians.
The All-In-One system that simplifies contrast
injection for all your interventional and diagnostic procedures
The unique AngioTouch® Hand Controller allows
real time variable-flow control of the contrast injection rate
for precise and consistent contrast administration.

CVi increases safety and operational efficiency.

Increase Patient Safety

  • Kidney Protection
    Up to 30% reduction
    in CI-AKI vs.
    manual injection.1
  • Air Embolism
    The following 5 key design elements were included in the CVi System to mitigate air injection:
    • Air column detect (ACD) sensor
    • Auto-purge/auto-refill
    • Syringe angle facilitates air purge
    • Bottom syringe port injection
    • Clear components

Increase Workplace Efficiency

  • Up to 50% reduction in clinician radiation exposure by stepping back

Increase Operational Efficiency

  • 45 mL decrease per case when injector used.

Delivering Value:Reducing Angiography Complications and Cost

Increase Patient Safety

  • Up to 30% reduction
    in CI-AKI vs. manual injection

    CI-AKI incremental cost range:
    $13,294 to $14,2662

  • ~25% reduction
    in contrast use without compromising image quality when comparing 4Fr to 6Fr diagnostic procedures

    Bleeding and contrast use were significantly reduced with 5Fr catheters compared with 6Fr

Increase Workplace Safety

  • Up to 50% reduction
    in clinician radiation exposure by stepping back

    4X higher skin lesions reported by interventional cardiologists

  • 49.4% of
    interventional cardiologists have experienced at least one orthopedic injury

    Manual contrast injection may cause repetitive stress injuries to the operator’s hand based on the force required to inject contrast and the number of procedures performed per day.

Increase Operational Efficiency

  • 45mL decrease
    per case when injector used

    Up to $0.30/mL savings in wasted contrast media

  • average 5 min faster
    per procedure

    Time saved may allow for additional procedures to be performed in a day11
    * P<0.05 ACIST CVi vs. manual injection

Delivering Value:Reducing Patient Risk through Deliberate Design

Patient safety and optimal outcomes are the top priority for any procedure. ACIST | CVi® System has facilitated the diagnosis and treatment of over 30 million coronary procedures while reducing angiographic risks through its robust design.

Contrast

Approximately 30% of patients presenting for coronary angiography procedures are at risk of post-procedure CI-AKI. The CVi System is able to reduce contrast volume for all patients requiring a diagnostic or interventional angiography through:
  • Parameter adjustments
  • Real-time dose tracking
  • Variable rate injection
  • Smaller Catheter Use
Up to 30% reduction
in CI-AKI vs. manual injection

Air Embolism

The CVi System has twelve design elements that mitigate air injection during angiography.
The following are the top features:
  • Air column detect (ACD) sensor
  • Auto-purge/auto-refill
  • Syringe angle facilitates air purge
  • Bottom syringe port injection
  • Clear components
The CVi System has 12 design elements
that mitigate air injection

Dissection

Variability in patient anatomy, disease state, procedural tools and treatment goals all contribute to complexity in catheter placement and the potential risk around contrast delivery. However, fewer than 1 in a million patients experience a coronary dissection using the CVi System. Safe patient diagnosis and treatment is in the physician’s hands with:
  • AngioTouch® hand controller
  • In-line pressure transducer
  • Proper catheter placement
Fewer than 1 in a million
patients experience a coronary dissection using the CVi System

AWARDED

It's Humed International's award trophy.

  • ACIST 2017 CVi Excellence
  • 2019 Excellence in CVi

CONTACT US

Thank you for visiting Humed International.
If you have any questions, please contact us.

HUMED
INTERNATIONAL
  • Address

    서울시 종로구 율곡로 190, 314호

  • Phone

    02-796-8111

  • Fax

    02-794-6500

  • E-Mail

    humed@humed.net

(주)휴메드인터내셔날/서울시 종로구 율곡로 190, 314호/전화: 02-796-8111/팩스: 02-794-6500/이메일: humed@humed.net

Copyright © Humed International. All rights reserved. Desined by. Design Fine Group.